{"product_id":"ac-high-capacity-freezer-860-tight-neck-opening-mdr","title":"AC High-Capacity Freezer 860 Tight Neck Opening - MDR","description":"\u003ch6\u003e#All\u003c\/h6\u003e\n\u003cp\u003eConsists of:\u003c\/p\u003e\n\u003ch6\u003e\u003cbr\u003e\u003c\/h6\u003e\n\u003ch5\u003e1. AC BIO 860\u003c\/h5\u003e\n\u003cp\u003eAuguste Cryogenics developed the stainless steel containers in this series from the ground up using state-of-the-art technology. They are specially designed for the safe and economical long-term storage of larger sample quantities and are therefore used in the fields of medicine, pharmaceuticals and research.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe vacuum-insulated products come with Auguste Cryogenics' GOLD-standard vacuum and offer a remarkably high storage capacity in a clear, smooth-running aluminum storage system on one level for the AC BIO series and two levels for the AC IVF series.  The containers of both series are characterized by very low nitrogen consumption at a stable storage temperature, which almost reaches the cold level of liquid nitrogen even in the gas phase.\u003c\/p\u003e\n\u003cp\u003eThe lid of the container opens easily and wide, allowing easy access to the contents. It is convenient to clean and is equipped with a control switch that, in addition to an \"open lid\" detection, can also send other control signals, for example for automatic demisting or rapid cooling.\u003c\/p\u003e\n\u003cp\u003eAuguste Cryogenics Medical Family Freezer Series vessels can be supplied with automatic filling and control systems to ensure a regulated supply of cryogenic liquid nitrogen and continuous monitoring.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines harmonized requirements across Europe for products intended for medical applications. MDR-compliant nitrogen containers meet the highest standards in terms of safety, quality, and documentation, and are specifically designed for use in sensitive environments such as medical, laboratory, and research settings.\u003cbr\u003eThey offer verified reliability, compliant design, and full traceability throughout the entire product lifecycle.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable style=\"width: 563px;\" class=\"iksweb\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003cth style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eAC BIO 860\u003c\/th\u003e\n\u003cth style=\"width: 292.812px; height: 19px;\"\u003ePart No. AC BIO 860\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e860\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eLN2 fill height [mm]\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e180\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eLN2 value below the base plate [l]\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e1150\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e1597\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eUsable height [mm]\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e740\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e446\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eEmpty weight (kg) (without ICS**)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e417\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eNumber of castors\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 19px;\" class=\"lefr-col\"\u003eNumber of storage carousels\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 19px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 25.0625px;\" class=\"lefr-col\"\u003eNumber of racks\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 25.0625px;\"\u003e26x of 10x10 Cryoboxes \/ 12x of 5x5 Cryoboxes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 25.0625px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 25.0625px;\"\u003e\u003cspan\u003e186.000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 25.0625px;\" class=\"lefr-col\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 25.0625px;\"\u003e\u003cspan\u003e82.800\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003ctd style=\"width: 254.188px; height: 25.0625px;\" class=\"lefr-col\"\u003e\u003cspan\u003e2ml Vials capacity (rack)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 292.812px; height: 25.0625px;\"\u003e\u003cspan\u003e37.700\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e* The values given are nominal values that were determined without storage system equipment \u003cbr\u003eand under precisely defined conditions. Depending on the operating conditions and the storage \u003cbr\u003esystem equipment used, the actual values can deviate considerably.\u003cbr\u003e** ICS = Inventory Control System\u003cbr\u003eDue to our policy of continuous product improvement, we reserve the right to change \u003cbr\u003especifications at any time without prior notice.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewith box to accommodate the piping and valves\u003c\/li\u003e\n\u003cli\u003ewithout storage system\u003c\/li\u003e\n\u003cli\u003eMDR\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cooling effect required for cryogenic sample storage is generated by the continuous evaporation of the liquid nitrogen refrigerant. The necessary heat of vaporization is extracted from the environment by heat transfer. As a result, the liquid nitrogen level in the deep-freeze storage tanks is constantly falling.\u003c\/p\u003e\n\u003cp\u003eRegular, controlled refilling is therefore required (automatically or manually). This results in the liquid level curve shown here. In order to prevent unnecessary nitrogen losses and icing of the storage containers, liquid nitrogen should be refilled at pressures between 0.7 bar - 1.4 bar only.\u003c\/p\u003e\n\u003cp\u003eThe insulating properties of the Auguste Cryogenics Medical Family are essentially based on the presence of a vacuum between the inner and outer container. A vacuum loss inevitably leads to a very high increase in nitrogen consumption and poses a risk for the stored samples if there is no refill with liquid nitrogen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eDownload data sheet \u0026amp; \u003cspan\u003etechnical drawing\u003c\/span\u003e:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/ACMF_Freezers_-_Brochure_EN_AC_50200.00.pdf?v=1698657321\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"80\" height=\"85\"\u003e       \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC_BIO_860_GA.pdf?v=1731589413\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"85\" width=\"80\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/ACMF_Freezers_-_Brochure_EN_AC_50200.00.pdf?v=1698657321\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch6\u003e#WITHAUTOFILLING-WITHRACKSTORAGESYSTEM\u003c\/h6\u003e\n\u003ch5\u003e2. CRYOFILL 2.0 PD WITH INSTALLATION ON A DEWAR, WITH MDR APPROVAL (MEDICAL DEVICE)\u003c\/h5\u003e\n\u003cp\u003eThe CryoFill 2.0 is the next generation liquid nitrogen level controller with a number of improved and new features. As well as the ability to have a real time remote read out of relevant data via an alarming and\/or monitoring system.\u003cbr\u003e\u003cbr\u003eNew features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarger, better and more user friendly 4.3” colour touchscreen display with a resolutions of 480x320\u003c\/li\u003e\n\u003cli\u003eReal-time remote read out, compatible with several monitoring systems\u003c\/li\u003e\n\u003cli\u003eOne Fill All Fill filling sequence\u003c\/li\u003e\n\u003cli\u003e(master slave configuration)\u003c\/li\u003e\n\u003cli\u003eHigh temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNew: One Fill All Fill (OFAF)\u003c\/p\u003e\n\u003cp\u003eThis is a feature for optimizing the filling sequence of multiple cryogenic storage vessels. The controllers are connected with each other using communication cables. The master controller will make sure all the vessels fill in succession, in order to minimize nitrogen consumption.\u003c\/p\u003e\n\u003cp\u003eNew: High temperature control\u003c\/p\u003e\n\u003cp\u003eThis is a new software feature for controlling the temperature in the neck of the vessel. This feature in intended for situation when work in performed in the neck and the lid is open for a longer period. In case the temperature in the neck starts to rise, the controller injects nitrogen into the vessel, which lowers the temperature in the top of the vessel.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe CryoFill 2.0 can be used for controlling the liquid nitrogen level for any storage type, either conventional gas phase or the so called “dry” gas phase, with an absolute separation between the samples and liquid nitrogen, or full liquid phase. The CryoFill 2.0 can easily retrofitted to existing cryogenic storage vessels of any brand or type.\u003c\/p\u003e\n\u003cp\u003eThe CryoFill 2.0 is equipped with the following features and options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser friendly interface\u003c\/li\u003e\n\u003cli\u003eCompatible with two measuring standards (pressure differential and 4 point measurement)\u003c\/li\u003e\n\u003cli\u003eTwo temperature sensors\u003c\/li\u003e\n\u003cli\u003eDefog and quick chill functions\u003c\/li\u003e\n\u003cli\u003eHot gas bypass\u003c\/li\u003e\n\u003cli\u003eSafety valve, acts as a secondary fill and bypass valve.\u003c\/li\u003e\n\u003cli\u003eUnit can be either build onto a vessel or into a cabinet (TW K-series) or into a lid (CBS V- series)\u003c\/li\u003e\n\u003cli\u003eTimed filling; Daily fill, weekly fill or fill pulse from cryobank control system\u003c\/li\u003e\n\u003cli\u003eData logging\u003c\/li\u003e\n\u003cli\u003eUPS battery back-up\u003c\/li\u003e\n\u003cli\u003eRemote real time read out of relevant data via RS485 \/ RS422\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNote: The product image is a sample illustration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload data sheet:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/CryoFill_2.0_CF2_MDR_Datasheet_R01_eng.pdf?v=1692005529\" rel=\"noopener\" target=\"_blank\"\u003e\u003cimg height=\"85\" width=\"80\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e3. RACK STORAGE SYSTEM FOR AC BIO 860\u003c\/h5\u003e\n\u003cp\u003eInventory system for storage of cryogenic vials. Complementary for container series AC BIO 860.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIt consists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e26x racks for 10x10 cryoboxes \u003c\/li\u003e\n\u003cli\u003e12x racks for 5x5 cryoboxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003efor storage of 2ml cryogenic vials. (cryoboxes are not included)\u003c\/p\u003e\n\u003cp\u003eMaximum storage capacity of 2ml cryo vials: 37.700 pcs.\u003c\/p\u003e\n\u003cp\u003eKey features of rack for 10x10 and 5x5 cryoboxes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e13 floors\u003c\/li\u003e\n\u003cli\u003eAluminum 1 mm\u003c\/li\u003e\n\u003cli\u003eLocking by means of spring retainer, \"snap lock\" on each floor\u003c\/li\u003e\n\u003cli\u003eHandle\u003c\/li\u003e\n\u003cli\u003eDimensions:\u003cbr\u003eRack for 10x10 cryoboxes - H735 x W138 x D136 mm\u003cbr\u003eRacks for 5x5 cryoboxes - H735 x W82 x D76 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003e#WITHAUTOFILLING-WITHCANISTERSTORAGESYSTEM\u003c\/h6\u003e\n\u003ch5\u003e2. CRYOFILL 2.0 PD WITH INSTALLATION ON A DEWAR, WITH MDR APPROVAL (MEDICAL DEVICE)\u003c\/h5\u003e\n\u003cp\u003eThe CryoFill 2.0 is the next generation liquid nitrogen level controller with a number of improved and new features. As well as the ability to have a real time remote read out of relevant data via an alarming and\/or monitoring system.\u003cbr\u003e\u003cbr\u003eNew features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarger, better and more user friendly 4.3” colour touchscreen display with a resolutions of 480x320\u003c\/li\u003e\n\u003cli\u003eReal-time remote read out, compatible with several monitoring systems\u003c\/li\u003e\n\u003cli\u003eOne Fill All Fill filling sequence\u003c\/li\u003e\n\u003cli\u003e(master slave configuration)\u003c\/li\u003e\n\u003cli\u003eHigh temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNew: One Fill All Fill (OFAF)\u003c\/p\u003e\n\u003cp\u003eThis is a feature for optimizing the filling sequence of multiple cryogenic storage vessels. The controllers are connected with each other using communication cables. The master controller will make sure all the vessels fill in succession, in order to minimize nitrogen consumption.\u003c\/p\u003e\n\u003cp\u003eNew: High temperature control\u003c\/p\u003e\n\u003cp\u003eThis is a new software feature for controlling the temperature in the neck of the vessel. This feature in intended for situation when work in performed in the neck and the lid is open for a longer period. In case the temperature in the neck starts to rise, the controller injects nitrogen into the vessel, which lowers the temperature in the top of the vessel.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe CryoFill 2.0 can be used for controlling the liquid nitrogen level for any storage type, either conventional gas phase or the so called “dry” gas phase, with an absolute separation between the samples and liquid nitrogen, or full liquid phase. The CryoFill 2.0 can easily retrofitted to existing cryogenic storage vessels of any brand or type.\u003c\/p\u003e\n\u003cp\u003eThe CryoFill 2.0 is equipped with the following features and options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser friendly interface\u003c\/li\u003e\n\u003cli\u003eCompatible with two measuring standards (pressure differential and 4 point measurement)\u003c\/li\u003e\n\u003cli\u003eTwo temperature sensors\u003c\/li\u003e\n\u003cli\u003eDefog and quick chill functions\u003c\/li\u003e\n\u003cli\u003eHot gas bypass\u003c\/li\u003e\n\u003cli\u003eSafety valve, acts as a secondary fill and bypass valve.\u003c\/li\u003e\n\u003cli\u003eUnit can be either build onto a vessel or into a cabinet (TW K-series) or into a lid (CBS V- series)\u003c\/li\u003e\n\u003cli\u003eTimed filling; Daily fill, weekly fill or fill pulse from cryobank control system\u003c\/li\u003e\n\u003cli\u003eData logging\u003c\/li\u003e\n\u003cli\u003eUPS battery back-up\u003c\/li\u003e\n\u003cli\u003eRemote real time read out of relevant data via RS485 \/ RS422\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNote: The product image is a sample illustration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload data sheet:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/CryoFill_2.0_CF2_MDR_Datasheet_R01_eng.pdf?v=1692005529\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"80\" height=\"85\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch5\u003e3. CANISTER STORAGE SYSTEM FOR AC BIO 860\u003c\/h5\u003e\n\u003cp\u003eInventory system for storage of cryogenic straws or vials. Complementary for container AC BIO 860.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIt consists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e120x aluminium canisters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003efor storing cryo straws in goblets or vials in vial holders. (goblets and vial holders are not included)\u003c\/p\u003e\n\u003cp\u003eStorage capacity:\u003c\/p\u003e\n\u003cp\u003eStraws 0,25ml: 186.000 pcs.\u003c\/p\u003e\n\u003cp\u003eStraws 0,5ml: 82.800 pcs.\u003c\/p\u003e\n\u003cp\u003eKey features of aluminium canisters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContains one lifter\u003c\/li\u003e\n\u003cli\u003eHas a perforated base\u003c\/li\u003e\n\u003cli\u003eHolds up to 5 goblets without lid, 64 mm diameter\u003c\/li\u003e\n\u003cli\u003eDimension: 715 mm x 70 mm (height x diameter)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCaution: This item is not suitable for goblets with lids\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eNote: The product image is a sample illustration.\u003c\/p\u003e\n\u003ch6\u003e#WITHAUTOFILLING-WITHOUTSTORAGESYSTEM\u003c\/h6\u003e\n\u003ch5\u003e2. CRYOFILL 2.0 PD WITH INSTALLATION ON A DEWAR, WITH MDR APPROVAL (MEDICAL DEVICE)\u003c\/h5\u003e\n\u003cp\u003eThe CryoFill 2.0 is the next generation liquid nitrogen level controller with a number of improved and new features. As well as the ability to have a real time remote read out of relevant data via an alarming and\/or monitoring system.\u003cbr\u003e\u003cbr\u003eNew features:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLarger, better and more user friendly 4.3” colour touchscreen display with a resolutions of 480x320\u003c\/li\u003e\n\u003cli\u003eReal-time remote read out, compatible with several monitoring systems\u003c\/li\u003e\n\u003cli\u003eOne Fill All Fill filling sequence\u003c\/li\u003e\n\u003cli\u003e(master slave configuration)\u003c\/li\u003e\n\u003cli\u003eHigh temperature control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNew: One Fill All Fill (OFAF)\u003c\/p\u003e\n\u003cp\u003eThis is a feature for optimizing the filling sequence of multiple cryogenic storage vessels. The controllers are connected with each other using communication cables. The master controller will make sure all the vessels fill in succession, in order to minimize nitrogen consumption.\u003c\/p\u003e\n\u003cp\u003eNew: High temperature control\u003c\/p\u003e\n\u003cp\u003eThis is a new software feature for controlling the temperature in the neck of the vessel. This feature in intended for situation when work in performed in the neck and the lid is open for a longer period. In case the temperature in the neck starts to rise, the controller injects nitrogen into the vessel, which lowers the temperature in the top of the vessel.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe CryoFill 2.0 can be used for controlling the liquid nitrogen level for any storage type, either conventional gas phase or the so called “dry” gas phase, with an absolute separation between the samples and liquid nitrogen, or full liquid phase. The CryoFill 2.0 can easily retrofitted to existing cryogenic storage vessels of any brand or type.\u003c\/p\u003e\n\u003cp\u003eThe CryoFill 2.0 is equipped with the following features and options:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUser friendly interface\u003c\/li\u003e\n\u003cli\u003eCompatible with two measuring standards (pressure differential and 4 point measurement)\u003c\/li\u003e\n\u003cli\u003eTwo temperature sensors\u003c\/li\u003e\n\u003cli\u003eDefog and quick chill functions\u003c\/li\u003e\n\u003cli\u003eHot gas bypass\u003c\/li\u003e\n\u003cli\u003eSafety valve, acts as a secondary fill and bypass valve.\u003c\/li\u003e\n\u003cli\u003eUnit can be either build onto a vessel or into a cabinet (TW K-series) or into a lid (CBS V- series)\u003c\/li\u003e\n\u003cli\u003eTimed filling; Daily fill, weekly fill or fill pulse from cryobank control system\u003c\/li\u003e\n\u003cli\u003eData logging\u003c\/li\u003e\n\u003cli\u003eUPS battery back-up\u003c\/li\u003e\n\u003cli\u003eRemote real time read out of relevant data via RS485 \/ RS422\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eNote: The product image is a sample illustration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload data sheet:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/CryoFill_2.0_CF2_MDR_Datasheet_R01_eng.pdf?v=1692005529\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"80\" height=\"85\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch6\u003e#WITHOUTAUTOFILLING-WITHRACKSTORAGESYSTEM\u003c\/h6\u003e\n\u003ch5\u003e2. RACK STORAGE SYSTEM FOR AC BIO 860\u003c\/h5\u003e\n\u003cp\u003eInventory system for storage of cryogenic vials. Complementary for container series AC BIO 860.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIt consists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e26x racks for 10x10 cryoboxes \u003c\/li\u003e\n\u003cli\u003e12x racks for 5x5 cryoboxes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003efor storage of 2ml cryogenic vials. (cryoboxes are not included)\u003c\/p\u003e\n\u003cp\u003eMaximum storage capacity of 2ml cryo vials: 37.700 pcs.\u003c\/p\u003e\n\u003cp\u003eKey features of rack for 10x10 and 5x5 cryoboxes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e13 floors\u003c\/li\u003e\n\u003cli\u003eAluminum 1 mm\u003c\/li\u003e\n\u003cli\u003eLocking by means of spring retainer, \"snap lock\" on each floor\u003c\/li\u003e\n\u003cli\u003eHandle\u003c\/li\u003e\n\u003cli\u003eDimensions:\u003cbr\u003eRack for 10x10 cryoboxes - H735 x W138 x D136 mm\u003cbr\u003eRacks for 5x5 cryoboxes - H735 x W82 x D76 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003e#WITHOUTAUTOFILLING-WITHCANISTERSTORAGESYSTEM\u003c\/h6\u003e\n\u003ch5\u003e2. CANISTER STORAGE SYSTEM FOR AC BIO 860\u003c\/h5\u003e\n\u003cp\u003eInventory system for storage of cryogenic straws or vials. Complementary for container AC BIO 860.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIt consists of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e120x aluminium canisters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003efor storing cryo straws in goblets or vials in vial holders. (goblets and vial holders are not included)\u003c\/p\u003e\n\u003cp\u003eStorage capacity:\u003c\/p\u003e\n\u003cp\u003eStraws 0,25ml: 186.000 pcs.\u003c\/p\u003e\n\u003cp\u003eStraws 0,5ml: 82.800 pcs.\u003c\/p\u003e\n\u003cp\u003eKey features of aluminium canisters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eContains one lifter\u003c\/li\u003e\n\u003cli\u003eHas a perforated base\u003c\/li\u003e\n\u003cli\u003eHolds up to 5 goblets without lid, 64 mm diameter\u003c\/li\u003e\n\u003cli\u003eDimension: 715 mm x 70 mm (height x diameter)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCaution: This item is not suitable for goblets with lids\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eNote: The product image is a sample illustration.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e#searchwords biobank storage tank biobank freezers high capacity cryo tank cryogenic storage tank biobank storage system vapor phase storage tank liquid phase ln2 storage biorepository cryogenic freezer cryogenic storage vessel cryogenic storage system cryogenic preservation system cryogenic archive system low temperature storage system long term sample storage biospecimen storage biobank storage system nitrogen vapor phase storage liquid phase cryostorage high capacity cryostorage automated cryostorage system sample archive system cryogenic dewar sample storage dewar cell banking system cryostorage for cell lines mammalian cell storage cell cryostorage cell line repository stem cell cryostorage stem cell biobank dna biobank rna sample storage biomaterial storage cell banking cryopreservation high density cryogenic storage platform biobankstoragetank biobankfreezers highcapacitycryotank cryogenicstoragetank biobankstoragesystem vaporphasestoragetank liquidphaseln2storage biorepository cryogenicfreezer cryogenicstoragevessel cryogenicstoragesystem cryogenicpreservationsystem cryogenicarchivesystem lowtemperaturestoragesystem longtermsamplestorage biospecimenstorage biobankstoragesystem nitrogenvaporphasestorage liquidphasecryostorage highcapacitycryostorage automatedcryostoragesystem samplearchivesystem cryogenicdewar samplestoragedewar cellbankingsystem cryostorageforcelllines mammaliancellstorage cellcryostorage celllinerepository stemcellcryostorage stemcellbiobank dnabiobank rnasamplestorage biomaterialstorage cellbanking cryopreservation highdensitycryogenicstorageplatform biobank storage tank biobank freezer hochkapazitäts kryotank kryogener lagertank biobank lagersystem dampfphasen lagertank flüssigphasen ln2 lagerung biorepositorium kryolagerbehälter kryotank kryobehälter flüssigstickstoff lagerbehälter ln2 lagertank kryolagersystem kryokonservierungssystem kryospeichersystem tieftemperatur lagersystem langzeit probenlager bioprobenlager biobank lagersystem stickstoff dampfphasenlager flüssigphasen kryolager hochkapazitäts kryolager automatisiertes kryolagersystem probenarchivierungssystem biorepositorium kryodewar dewar gefäß probenlagerdewar cell banking system zellbank lagersystem kryolager für zelllinien lagerung von säugerzellen zell kryolager zelllinien repository stammzell kryolager stammzell biobank dna biobank rna probenlager biomateriallager cell banking kryokonservierung hochdichte kryogene lagerplattform biobankstoragetank biobankfreezer hochkapazitätskryotank kryogenerlagertank biobanklagersystem dampfphasenlagertank flüssigphasenln2lagerung biorepositorium kryolagerbehälter kryotank kryobehälter flüssigstickstofflagerbehälter ln2lagertank kryolagersystem kryokonservierungssystem kryospeichersystem tieftemperaturlagersystem langzeitprobenlager bioprobenlager biobanklagersystem stickstoffdampfphasenlager flüssigphasenkryolager hochkapazitätskryolager automatisierteskryolagersystem probenarchivierungssystem biorepositorium kryodewar dewargefäß probenlagerdewar cellbankingsystem zellbanklagersystem kryolagerfürzelllinien lagerungvonsäugerzellen zellkryolager zelllinienrepository stammzellkryolager stammzellbiobank dnabiobank rnaprobenlager biomateriallager cellbanking kryokonservierung hochdichtekryogenelagerplattform\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eLN2 capacity in gas storage (liters): 102 \u003cbr\u003eLN2 capacity in liquid storage (liters): 860\u003cbr\u003eEmpty weight (kg): 400\u003cbr\u003eNeck opening (mm): 446,8\u003cbr\u003eOutside diameter (mm): 1150\u003cbr\u003eTotal height (mm): 1544\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"WITH AUTO-FILLING \/ WITH RACK STORAGE SYSTEM","offer_id":57000978809097,"sku":"AC BIO 860 - MDR + CryoFill 2.0 PD MDR with Installation + Rack Storage System for AC BIO 860","price":52527.0,"currency_code":"EUR","in_stock":true},{"title":"WITH AUTO-FILLING \/ WITH CANISTER STORAGE SYSTEM","offer_id":57000978841865,"sku":"AC BIO 860 - MDR + CryoFill 2.0 PD MDR with Installation + Canister Storage System for AC BIO 860","price":53251.0,"currency_code":"EUR","in_stock":true},{"title":"WITH AUTO-FILLING \/ WITHOUT STORAGE SYSTEM","offer_id":57000978874633,"sku":"AC BIO 860 - MDR + CryoFill 2.0 PD MDR with Installation","price":45691.0,"currency_code":"EUR","in_stock":true},{"title":"WITHOUT AUTO-FILLING \/ WITH RACK STORAGE SYSTEM","offer_id":57000978907401,"sku":"AC BIO 860 - MDR + Rack Storage System for AC BIO 860","price":42160.0,"currency_code":"EUR","in_stock":true},{"title":"WITHOUT AUTO-FILLING \/ WITH CANISTER STORAGE SYSTEM","offer_id":57000978940169,"sku":"AC BIO 860 - MDR + Canister Storage System for AC BIO 860","price":42884.0,"currency_code":"EUR","in_stock":true},{"title":"WITHOUT AUTO-FILLING \/ WITHOUT STORAGE SYSTEM","offer_id":57000978972937,"sku":"AC BIO 860 - MDR","price":35324.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/AC_BIO430_Cell_Storage_Cryogenic_Nitrogen_High-Capacity_Freezer_Cryopreservation_Cryoconservation_Grossraum_Gefrierbehaelter_Kryokonservierung_Kryolagerung_1.1_922cc45d-9f2d-4d71-95eb-baae598e0170.png?v=1731235526","url":"https:\/\/cryonos.shop\/products\/ac-high-capacity-freezer-860-tight-neck-opening-mdr","provider":"Cryonos GmbH","version":"1.0","type":"link"}