{"product_id":"ac-ivf-430","title":"AC IVF 430","description":"\u003cp\u003eAuguste Cryogenics developed the stainless steel containers in this series from the ground up using state-of-the-art technology. They are specially designed for the safe and economical long-term storage of larger sample quantities and are therefore used in the fields of medicine, pharmaceuticals and research.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe vacuum-insulated products come with Auguste Cryogenics' GOLD-standard vacuum and offer a remarkably high storage capacity in a clear, smooth-running aluminum storage system on one level for the AC BIO series and two levels for the AC IVF series.  The containers of both series are characterized by very low nitrogen consumption at a stable storage temperature, which almost reaches the cold level of liquid nitrogen even in the gas phase.\u003c\/p\u003e\n\u003cp\u003eThe lid of the container opens easily and wide, allowing easy access to the contents. It is convenient to clean and is equipped with a control switch that, in addition to an \"open lid\" detection, can also send other control signals, for example for automatic demisting or rapid cooling.\u003c\/p\u003e\n\u003cp\u003eAuguste Cryogenics Medical Family Freezer Series vessels can be supplied with automatic filling and control systems to ensure a regulated supply of cryogenic liquid nitrogen and continuous monitoring.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMDR – Medical Device Regulation (EU)\u003c\/strong\u003e\u003cbr\u003eThe Medical Device Regulation (MDR) defines harmonized requirements across Europe for products intended for medical applications. MDR-compliant nitrogen containers meet the highest standards in terms of safety, quality, and documentation, and are specifically designed for use in sensitive environments such as medical, laboratory, and research settings.\u003cbr\u003eThey offer verified reliability, compliant design, and full traceability throughout the entire product lifecycle.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"mobile-table\"\u003e\n\u003ctable class=\"iksweb\" style=\"width: 541px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003cth class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eAC IVF 430\u003c\/th\u003e\n\u003cth style=\"width: 230.812px; height: 19px;\"\u003ePart No. AC IVF 430\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eLN2 capacity (liters)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e430\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eLN2 fill height [mm]\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e135\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eLN2 value below the base plate [l]\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eOutside diameter (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e800\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eTotal height (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e1,419\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eUsable height [mm]\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e2x 370\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eNeck opening (mm)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e317\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eEmpty weight (kg) (without ICS**)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e229\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eStatic evaporation rate (liters \/ day)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eStatic hold time (days)\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eNumber of castors\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 19px;\"\u003eNumber of storage carousels\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 19px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 25.0625px;\"\u003e\u003cspan\u003eStraw holding capacity 0,25 ml \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 25.0625px;\"\u003e\u003cspan\u003e123.690\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 25.0625px;\"\u003e\n\u003ctd class=\"lefr-col\" style=\"width: 294.188px; height: 25.0625px;\"\u003e\u003cspan\u003eStraw holding capacity 0,5 ml\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 230.812px; height: 25.0625px;\"\u003e\u003cspan\u003e55.062 \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e* The values given are nominal values that were determined without storage system equipment \u003cbr\u003eand under precisely defined conditions. Depending on the operating conditions and the storage \u003cbr\u003esystem equipment used, the actual values can deviate considerably.\u003cbr\u003e** ICS = Inventory Control System\u003cbr\u003eDue to our policy of continuous product improvement, we reserve the right to change \u003cbr\u003especifications at any time without prior notice.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003etwo-storey carousel\u003c\/li\u003e\n\u003cli\u003ewith box to accommodate the piping and valves\u003c\/li\u003e\n\u003cli\u003ewithout storage system\u003c\/li\u003e\n\u003cli\u003eoptional available as an MDR product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cooling effect required for cryogenic sample storage is generated by the continuous evaporation of the liquid nitrogen refrigerant. The necessary heat of vaporization is extracted from the environment by heat transfer. As a result, the liquid nitrogen level in the deep-freeze storage tanks is constantly falling.\u003c\/p\u003e\n\u003cp\u003eRegular, controlled refilling is therefore required (automatically or manually). This results in the liquid level curve shown here. In order to prevent unnecessary nitrogen losses and icing of the storage containers, liquid nitrogen should be refilled at pressures between 0.7 bar - 1.4 bar only.\u003c\/p\u003e\n\u003cp\u003eThe insulating properties of the Auguste Cryogenics Medical Family are essentially based on the presence of a vacuum between the inner and outer container. A vacuum loss inevitably leads to a very high increase in nitrogen consumption and poses a risk for the stored samples if there is no refill with liquid nitrogen.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eDownload data sheet:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/ACMF_Freezers_-_Brochure_EN_AC_50200.00.pdf?v=1698657321\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/files\/pdfArtboard_1.png?v=1585782429\" width=\"80\" height=\"85\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003eLN2 capacity (liters): 430\u003cbr\u003eEmpty weight (kg): 229\u003cbr\u003eNeck opening (mm): 317\u003cbr\u003eOutside diameter (mm): 800\u003cbr\u003eTotal height (mm): 1,419\u003cbr\u003eStatic evaporation rate (liters\/day): 9\u003cbr\u003e\u003ciframe style=\"display: none;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e","brand":"Auguste Cryogenics","offers":[{"title":"NO MDR","offer_id":56969380069641,"sku":"AC IVF 430","price":18150.0,"currency_code":"EUR","in_stock":true},{"title":"MDR","offer_id":56969380102409,"sku":"AC IVF 430 - MDR","price":19800.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0285\/7979\/0981\/products\/AC_IVF430_Cell_Storage_Cryogenic_Nitrogen_Freezer_1.png?v=1675872913","url":"https:\/\/cryonos.shop\/products\/ac-ivf-430","provider":"Cryonos GmbH","version":"1.0","type":"link"}