High-Capacity Freezer series · Medical Family

Biobank scale.
Filled automatically.

The stainless-steel High-Capacity Freezers store 430 to 860 litres of liquid nitrogen and up to 186,000 straws or 37,700 cryovials. The wide lid opens easily and a lid switch reports “open”. With automatic filling and monitoring, the level stays stable even with daily access. Available with racks (BIO), canisters on two levels (IVF) or the wide-neck SYS frame for liquid or vapour phase.

Sales & service for
LN₂ capacity
430–860 L
Neck opening
317–800 mm
Straws, max.
186,000
Models
6
  • Manufacturer: Auguste Cryogenics
  • 5-year manufacturer’s warranty on the vacuum
  • MDR version available
  • Spare parts for the whole service life
What sets the series apart

Tight neck opening or wide neck opening.

A tight neck opening keeps the nitrogen consumption low. The wide neck opening of the Freezer 480 opens the whole cross-section, so you can reach every rack directly. All 3 sizes, neck openings drawn to scale:

Storage system

Racks, canisters or frame

The storage system is chosen as a variant of each freezer. All run in an aluminium frame that turns smoothly, so you reach every position through the lid.

  • BIO · Racks for cryoboxesOne level.
  • IVF · Canisters on two levelsFor straws.
  • SYS 480 · Wide-neck frameFor the liquid or the vapour phase.
BIO

Rack with boxes

Levels
1
Cryovials
up to 37,700
IVF

Canisters

Levels
2
Straws 0.25 ml
up to 117,800
SYS

Frame, 480 wide neck opening

Phase
liquid or vapour
Straws 0.25 ml
–
Reading a model name

Freezer options, decoded.

Each freezer is configured with its variants: levels, storage system, automatic filling and MDR.

430Litres LN₂
BIORacks, 1 level
IVFCanisters, 2 levels
AUTOAutomatic filling
MDRMedical device version
Good to know before you choose

What the numbers mean in daily use.

Consumption instead of holding time

Freezers are refilled continuously, so they are rated by nitrogen consumption: about 9 litres per day. Automatic filling keeps the level constant.

Liquid or vapour phase

The Freezer 480 with SYS frame stores in the liquid or the vapour phase. In the vapour phase, samples stay close to the temperature of liquid nitrogen without being submerged.

Installation and service

227 to 420 kg empty, on castors. We deliver, install and commission the freezer, and service it on site. Automatic filling needs a supply vessel, for example an AC 240 PB.

Smaller vessels

For smaller volumes or longer holding time per filling see the AC 3XL and AC 2XL series.

Still comparing series? Our guide explains sample formats, quantities and refill intervals step by step.

Read: Choosing the right container for cell storage
All High-Capacity Freezer models

Compare at a glance.

Not sure which size?

Let the cell storage finder choose.

Four questions about sample format, quantity and refill interval. The finder opens directly on the cell storage path and suggests the right model across all series.

  1. What do you store: straws, cryovials or both?
  2. How many samples, now and in five years?
  3. How often can you refill?
  4. Stationary or also transported?