The vacuum-insulated aluminum containers of the L, XL+, 2XL, 2XL+, and 3XL series of the Auguste Cryogenics Medical Family are cryogenic storage vessels for the long-term storage of biological material in liquid nitrogen – with numerous application possibilities in laboratories as well as in medical, pharmaceutical, and industrial facilities.
Key Features:
The individual vessel series mainly differ in their neck diameters (50, 90, 125, 127, and 216 mm) and are supplied as standard with short (-S, 120 mm) or long (-L, 276 mm) canisters, or racks with cryoboxes (-B). The short canisters are primarily used for the storage of cryogenic straws, while the long canisters each contain two goblets and are suitable for both straws and cryovials in holders. The racks are designed for the systematic storage of cryovials and are only used in the 2XL and 3XL series. These vessels are ideally suited for the structured storage of medium to large sample volumes in the liquid nitrogen phase; with long canisters and racks, storage in the gas phase may also be possible. Depending on the model and configuration, static holding times of three weeks to over half a year are possible.
A complete overview of all technical parameters for this container is provided in the “Technical Data” table below.
Overview of further models for CELL STORAGE:
T-Models
T-models are reinforced cryogenic storage and transport vessels. They are based on the L, XL+, 2XL, and 2XL+ series, but differ in their reinforced construction and are therefore designed for the safe transport of biological samples in liquid nitrogen. The “T” stands for transport: the vessels comply with ADR regulations for transport on public road and rail networks. These vessels combine storage and mobility, but are usually a compromise with regard to evaporation rate and holding time.
Example: AC L20-S (standard) and AC L20T-S (T-version).
AC FREEZER
Freezers are high-capacity stainless-steel cryogenic storage vessels specifically developed for the safe and economical long-term storage of larger sample quantities. They are used in medicine, pharmaceuticals, and research and are available with a capacity of 430 L, 480 L, or 860 L. The vessels are suitable for both gas-phase and liquid-phase storage. They can also be equipped with canisters, rack systems, and automatic filling and monitoring systems, and are ideal for research institutions, biobanks, and universities with high capacity requirements.
If you need assistance selecting the appropriate container, please consult our guide “Cryogenic Cell Storage: The Guide to Selecting the Right Container” or contact us directly.
MDR – Medical Device Regulation (EU)
The Medical Device Regulation (MDR) defines binding requirements across Europe for products intended for medical applications. MDR-compliant liquid nitrogen vessels are required for medical and regulated applications where safety, documentation, and traceability are required – for example in hospitals, IVF centers, or biobanks.
Technical Data
| AC 2XL47-L (10) | Part No. H-AAA1100319 |
|---|---|
| LN2 capacity (liters) | 47 |
| Empty weight (kg) | 18,2 |
| Neck opening (mm) | 127 |
| Outside diameter (mm) | 508 |
| Total height (mm) | 770 |
| Static evaporation rate (liters / day) | 0,36 |
| Static hold time (days) | 130 |
| Canister diameter (mm) | 72 |
| Canister height (mm) | 276 |
| Canister Number | 10 |
| Straw holding capacity 0,25 ml (-L) | 16400 |
| Straw holding capacity 0,5 ml (-L) | 8200 |
| 2ml Vials capacity | 684 |
| ADR | no |
| available as an MDR product | yes (optional) |
| Packing dimensions (mm) | 540*540*890 |
| Shipping volume (m3) | 0,26 |
| Weight including packaging (kg) | 28,7 |
* The values given are nominal values, determined without a storage system and under
precisely defined conditions. Depending on the operating conditions and the
storage system used, the actual values may vary considerably.
In the course of continuous product improvement and development,
we reserve the right to change the specifications at any time without prior notice.
Including 10 long canisters and 20 goblets
Download datasheet
#searchwords AC2XL AC2XL47 AC2XL47L AC2XL47L10 AC2XL47-L 2XL 2XL47 2XL47-L 2XL47L Probenlagerung Aluminium Probenlager Behälter Kryolagerbehälter Gefrierbehälter Langzeitlagerung Zelllagerung Kryokonservierung Vitrifikation Kryolagerung Cryoconservation Lagerung biologischer Proben Kryoaufbewahrung Kryobehälter Probentank Zelltank Probenzellentanks Tiefsttemperatur-Gefrierbehälter Freezer Cell storage longterm long-term freezing container Sample storage Cryostorage Cryonos cryogenic container liquid nitrogen container LN2 container cryogenic storage vessel biological sample storage cryogenic dewar liquid nitrogen tank sample storage container laboratory cryogenic vessel cell storage vessel Kryobehälter Flüssigstickstoffbehälter Stickstoffbehälter Kryotank Lagerbehälter Zelllagerung Kryolagerung Probenlagerung Biobank Behälter Laborbehälter MDR M D R Medical Device Regulation Medizinprodukt Auguste Cryogenics AC 2XL47-L (10) AC 2XL47-L (10) liquid nitrogen container AC 2XL47-L (10) cryogenic storage vessel AC 2XL47-L (10) Flüssigstickstoffbehälter AC 2XL47-L (10) Kryobehälter AC 2XL47-L 10 AC 2XL47 L 10 AC 2XL47L 10 AC2XL47-L 10 AC2XL47L 10 XL2XL47-L 10 XL2XL47 L 10 XL2XL47L 10 2XL47-L 10 2XL47 L 10 2XL47L 10 AC 2XL47-L AC 2XL47 L AC 2XL47L AC2XL47-L AC2XL47L 2XL47-L 2XL47 L 2XL47L AC 2XL47 AC2XL47 AC 2XL47 L AC2XL47L AC 2XL 47-L AC 2XL 47 L AC 2XL 47L 2XL 47-L 2XL 47 L 2XL 47L AC2XL47 AC2XL47-L AC2XL47L 2XL47 AC2XL47L 2XL47 AC2XL47 AC2XL47L H-AAD1100319 HAAD1100319 H AAD1100319 H-AAD-1100319 H-AAD 1100319 HAAD 1100319 AAD1100319 AAD 1100319 1100319 H-AAD2100319 HAAD2100319 H AAD2100319 H-AAD-2100319 H-AAD 2100319 HAAD 2100319 AAD2100319 AAD 2100319 2100319